Get complete information related to latest Boom Barrier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Boom Barrier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Boom Barrier Tenders.
Tender For providing, installation, testing & commissioning of door frame metal detector 33 zone digital type, barricades, boombarrier system and alcohol detectors at btps
Tender For corrigendum : supply of repair of upa 1kva online , repair of management console computer , repair of work station computer , repair ofsound amplifier 15000w fo 100nos , speaker , usb mixer , wd4tb nas hard with box , speaker wire , external for storage of camera feed , repair of boombarrier with tyer killer
Tender For corrigendum : supply of repair of high definition camera with ni vision capability poe ip , utp cable cat 6 , nvr with i p and 2 tb hard disc 16 port , repair of ptz programming console , repair of display monitor 40 inch , repair of boombarrier with tyre killed , ptz camera 100 mtr , repair of mega phones , repair of license plate camera , repair of rfid sys with lan , repair of rfid cards with lanyard , switch 24 port 1000mbps , repair of management console , repair of servers , repair of biometricd gate lock , repair of search light , repair of hhm detector , electrical siren 2 km , repair of integrated racks , repair of ups 1 kva offline , repair of ups 5 kva online with 1 hrs backup , ofc 4 core , monitor 18.5 inch , hand held rfid system , repair of door frame metal detector , media converter
Tender For corrigendum : supply of repair of boombarrier , repair of ptz camera , repair of megaphone , repair of licnse plate camera , repair of rfid sys with lan , repair of rfid cards with lanyard , repair of management console , repair of bio metric door lock , repair of high capicity search light , hand held metal detector , repair of electric siren , repair of online ups 5 kva , nas 2tb , traffic cones , repair of printer , onu , repair of gepon , under vehicle search mirror , repair of digiatal video camera
Tender For supply of washer spring single coil type b steel 12 mm , blade hack saw hand flexible coarse nominal length 300 mm , blade hack saw hand flexible fine nominal length 300 mm , gases acetylene 3 kg , washer spring single coil type b steel nominal size 6mm , pins cotter split steel 1point 6 mm by 25 mm , pins cotter split steel 1point 6 mm by 40 mm , pins cotter split steel 2point 5mm by 80 mm , pins cotter split steel 5point 5mm by 63 mm , nails brad steel cut 20 mm by 1point 50 mm , washer spring single coil type b steel nominal size 2 point 5 mm , washer spring single coil type b steel nominal size 7mm , washer spring single coil type b steel nominal size 10 mm , washer spring single coil type b 14 mm , washer spring single coil type b steel nominal n size 16 mm , washer spring single coil type b 18 mm , washer spring single turn 20 mm , pins cotter split steel 2 point 5 mm by 25 mm , pins cotter split steel 2 point 5 mm by 50 mm , pins cotter split steel 2 point 5 mm by 80 mm , rivets snap head copper dia 3 by 20mm , rivets snap head copper 6mm by 40mm , rivets snap head copper 8mm by 20mm , pins cotter split steel 3 point 2 mm by 25 mm , wire brass soft 3 point 251 mm , electrode welding high alloy steel 3point 15mm , flux welding aluminium 110 g container , tubing copper round seamless od 8mm by wt 0 point 80mm , tubing copper round seamless od 12mm by wt 0 point 80mm , tubing copper round seamless od 16mm by wt 1point 20mm , rod welding iron cast super silicon 3 point 15 , rod welding iron cast super silicon 6point 30 , rod welding copper 4 point 00mm , abrasive cloth emery or corundum grit no 100 , abrasive paper glass is grit 120 size 0 , abrasive paper emery or corundum is grit , soap laundry , adhesive padding glue mowicol l , adhesive syn resin araldite ay 103 , adhesive well seal , adhesive synthetic resin araldite ay 105 , quick fix , soap toilet , fevicol sr 998 , graphite dry flake , abrasive paper emery or corundum is grit 180 , inhictor c vapour barrier water soluble , detergent solution , cement for brass allu to rubber joint , adhesive universal , tubing rubber internal diameter 6 point 3 mm , tubing rubber internal diameter 10 mm , tubing rubber internal diameter 20mm , tape adhesive w roof w 40mm by l65 , m seal , cork sheet 1 point 6 mm thick , cork sheet thick 2 point 4mm , jointing asb f comp gr 0 point 8 mm 100 by100 cm , jointing asb f comp gr 1point 6 mm 100 by100 cm , jointing asb f comp gr 3point 2 mm thick , packing asbestos round 6 point 4mm , packing asb braaided yarn core rd 9point 5 mm , asbestos mild board 1point 6 mm , insulating pvc tape width 20 mm , insulation tape electrical cotton self adhesive
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boombarrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene